logo
Found 90 products for "

endoscope repair service

"
Qualidade Maio-1443 Peças de endoscopia flexíveis para endoscópicos Olympus válvula de sucção Fábrica

Maio-1443 Peças de endoscopia flexíveis para endoscópicos Olympus válvula de sucção

Detail olympus suction valve maj-1443 for eus endoscopes Olympus SUCTION VALVE MAJ-1443 Brand: Olympus Series: SUCTION VALVE Model:MAJ-1443 Description .Suction Valve, Autoclavable, Non-Sterile, Reusable, For EUS Endoscopes . Helps prevent backflow . Reusable CareUtech is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound,

Qualidade Processador de vídeo PENTAX Medical EPK-i7000 para reparação Fábrica

Processador de vídeo PENTAX Medical EPK-i7000 para reparação

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: Six months. ►Problem & Solution Brand PENTAX Model EPK-i7000 Product Processor Fault It cannot recognize the endoscope and reports an error. Solution Repair the system board. ►

Qualidade Histeroscópio autoclavável Olympus A4674A para reparo Fábrica

Histeroscópio autoclavável Olympus A4674A para reparo

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur

Qualidade Karl Storz 27005BA Cystoscope for repair Fábrica

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualidade Olympus A70940A Artroscópio autoclavável para reparação Fábrica

Olympus A70940A Artroscópio autoclavável para reparação

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

Qualidade Equipamento Médico Olympus reparado Solução definitiva para Serviços Médicos Fábrica

Equipamento Médico Olympus reparado Solução definitiva para Serviços Médicos

Product Description: Product Summary: The Medical Device Repair Cases product offered is a comprehensive solution for repairing and maintaining Olympus medical devices. With a warranty of 90 days, customers can have peace of mind knowing that their repaired devices are covered for an extended period. These repaired devices are in good condition, ensuring that they function effectively and reliably. The faults that have been addressed include light bundle broken, insert tube

Qualidade Reparação de aparelhos médicos Casas de GE RIC5-9-D sonda de ultra-som para reparação Fábrica

Reparação de aparelhos médicos Casas de GE RIC5-9-D sonda de ultra-som para reparação

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.

Qualidade OLYMPUS CF-HQ190L Caixas de reparação de dispositivos médicos Caixa de ferramentas de reparação Fábrica

OLYMPUS CF-HQ190L Caixas de reparação de dispositivos médicos Caixa de ferramentas de reparação

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not good sealed and leaking. Solution: Replace biopsy channel, bending section, wire, helix tube, light guide tube, rubber Company Profile Guangzhou Careutech Co., Ltd. supplies medical

Qualidade OLYMPUS CF-H180AL Colonoscópio Eletrônico Para Reparação Fábrica

OLYMPUS CF-H180AL Colonoscópio Eletrônico Para Reparação

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and the snake bone is deformed. 5. The light guide tube is slightly wrinkled. Solution: Repair and Replacement: CCD, light bundle, insertion tube, biopsy tube, snake bone, steel wire,