endoscope repair service

"
Qualidade Reparação de aparelhos médicos Casas de GE RIC5-9-D sonda de ultra-som para reparação Fábrica

Reparação de aparelhos médicos Casas de GE RIC5-9-D sonda de ultra-som para reparação

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in ...

Qualidade OLYMPUS CF-HQ190L Caixas de reparação de dispositivos médicos Caixa de ferramentas de reparação Fábrica

OLYMPUS CF-HQ190L Caixas de reparação de dispositivos médicos Caixa de ferramentas de reparação

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not ...

Qualidade GE 4D3C-L 4D Transdutor Convexo para Reparação Fábrica

GE 4D3C-L 4D Transdutor Convexo para Reparação

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...

Qualidade GE 4C-RS sonda abdominal para reparação Fábrica

GE 4C-RS sonda abdominal para reparação

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS ...

Qualidade S5-2 Proba cardíaca para reparação Fábrica

S5-2 Proba cardíaca para reparação

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain ...

Qualidade Toracoscópio Olympus LTF-160 para reparo Fábrica

Toracoscópio Olympus LTF-160 para reparo

Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...

Qualidade OLYMPUS CF-H180AL Colonoscópio Eletrônico Para Reparação Fábrica

OLYMPUS CF-H180AL Colonoscópio Eletrônico Para Reparação

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Qualidade SonoScape EG-500 Gastroscopia Eletrônica para Reparação Fábrica

SonoScape EG-500 Gastroscopia Eletrônica para Reparação

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...

Qualidade Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube Fábrica

Olympus Flexible Endoscope Air & Water Tube A/W Transparent Tube

Olympus/ Pentax/ Fuji A/W Tube ► Brief Description The "air/water channel" is a critical part of a flexible endoscope's function. The tube you are referring to is most commonly known as the Air/Water Valve Tube or A/W Tube . It's a small, transparent, and highly flexible tube that connects the air ...